Heaters

Manufacturers

Click the logos for more information.

Featured Products

Indeeco Pipe Thread Heaters

1-In--Pipe-Thread

Featured Items:

Element bends repressed uniformly to insure electrical insulation integrity. One-piece forging of hex, thread and riser assures reliability. Element spacers prevent hot spots. Bussing is permanent and encapsulated in epoxy seal. UL CSA label furnished on all standard copper, stainless steel and Incoloy sheathed heaters, NEMA Type 1, 4 and 4x environments.

General Info

Immersion Heaters are designed for direct immersion in liquids such as water, oils, solvents and process solutions, molten materials as well as air and gases. The different types of immersion heaters are screw plug immersion heaters, flanged immersion heaters, over the side immersion heaters, pipe insert immersion heaters and more. Please call (717) 630-2222 with any specifications, part numbers, model numbers, and other information such as thread size, material being heated, wattage, voltage, etc...and we will be happy to design a heater to match your needs.

Dalton Watt-flex Split-Sheath Cartridge Heaters

wattflex

The Revolutionary Watt-Flex® Split-Sheath Cartridge Heater maximizes heat transfer, reduces maintenance costs, and reduces the cost of process heating. Hot Tip or Cool Tip Option. Watt-Flex Cartridge Heaters run more efficiently, use less power and last up to 5 times longer than conventional cartridge heaters.

General Info

Cartridge Heaters are used for heating metal parts in liquid heating applications. They are inserted into drilled holes to heat metal parts or small spaces. They are used in the extrusion process as well as in the jaws of packaging machines for form, fill, and seal. Please call (717) 630-2222 with any specifications, part numbers, model numbers, and other information such as wattage, voltage, heater diameter and length and lead type and length, etc...and we will be happy to design a heater to match your needs.

Mica Insulated Band Heaters

band_product_info

Mica insulated band heaters are available in one or two-piece construction and a variety of diameters and widths. One-piece band heaters are manufactured with inside diameters from 1 to 31/2 inches. Two-piece band heaters are available in diameters from 4 to 111/2 inches. Electrical connections are made through post terminals or insulated and stainless steel overbraided leads. Each half of the two-piece band heaters are rated 120 Volts, and are wired in parallel for 120 Volt operation, or in series for 240 Volt operation. Available options include different dimensions and terminals, special wattage or voltage ratings, flexible conduit and holes or cutouts. Two, or more sections can be manufactured to fit larger diameters.

General Info

Band Heaters are designed to apply heat by conduction to cylindrical surfaces. Typical applications for barrel type band heaters include heating of barrels of plastic injection molders and extruders, heat-treating large diameter pipe sections, heating kettles and fluidized beds. Nozzle heaters are smaller in diameter than band heaters and are used to heat smooth steel nozzles. Different types of band heaters include MICA band heaters, ceramic band heaters, and mineral insulated band heaters. Please call (717) 630-2222 with any specifications, part numbers, model numbers, and other information such as wattage, voltage, heater width, Internal diameter, lead type, etc...and we will be happy to design a heater to match your needs.

Electric Duct Heater

electric_duct_heater

Process Air Heaters are your solution for heating forced air in industrial systems efficiently and economically. Our reputation has been built on custom-designed heaters where we control the complete design and manufacturing process. This includes the manufacture of heating elements; complex metal framing; control enclosures and electronic controls.

General Info

Process Air Heaters are installed in plenums, ducts or pipes to heat forced air in industrial equipment and systems. A wide variety of heater designs and sizes are available to provide outlet air temperatures up to 1200° F. The air can be either recirculated or fresh. Recirculated air is used to reduce power consumption and heater size. Fresh air is used when ventilation of the process is necessary. Process air heaters are installed in ovens, furnaces, autoclaves, dryers, conveyor systems, pressure vessels, and other equipment to supply the precise amount of clean heat.

Silicone Rubber Heaters

marathonheaterimage

Flexible heaters provide outstanding performance in applications up to 450°F under a variety of operating conditions. Properly applied silicone rubber heater life routinely exceeds 10 years. Silicone rubber has a high dielectric strength and is flame-retardant and non-toxic. Design versatility permits special heat profiles allowing zones of higher or lower heat concentration as needed. Their flexible construction makes them very easy to install on a variety of surfaces. Silicone Rubber Heaters can be mounted to flat or curved surfaces. They are not affected by vibration, flexing or repeated mechanical shock.

General Info

Silicone Rubber Heaters are thin, lightweight and flexible, yet rugged heaters that can be used for many applications including freeze protection and condensation prevention for many types of instrumentation and equipment, medical equipment such as blood analyzers and test tube heaters, computer peripherals such as laser printers, curing of plastic laminates, photo processing equipment and semiconductor processing equipment. They can be mounted with pressure-sensitive adhesive, mechanical fasteners, field applied adhesive, silicone contact cement, etc... Please call (717) 630-2222 with any specifications, part numbers, model numbers, and other information such as wattage, voltage, heater length and width and lead type, with or without thermostat, lock up type, with or without adhesive, etc...and we will be happy to design a heater to match your needs.

InteliHeat

InteliHeat

Featured Items:

5 US gal (25 liter) Size 'A'

  • HJNA/A/OR - Used for gentle warming (freeze protection), comes with fixed thermostat 50C (122F)
  • HHNA/A/OR - Used for heating materials, comes with adjustable thermostat 0-90C (32-194F)
  • HPNA/A/OR - Used for maximum heating, comes with adjustable thermostat 0-160C (32-320F)

15 US gal (50 liter) Size 'B'

  • HJNA/B/OR - Used for gentle warming (freeze protection), comes with fixed thermostat 50C (122F)
  • HHNA/B/OR - Used for heating materials, comes with adjustable thermostat 0-90C (32-194F)
  • HPNA/B/OR - Used for maximum heating, comes with adjustable thermostat 0-160C (32-320F)

30 US gal (100 liter) Size 'C'

  • HJNA/C/OR - Used for gentle warming (freeze protection), comes with fixed thermostat 50C (122F)
  • HHNA/C/OR - Used for heating materials, comes with adjustable thermostat 0-90C (32-194F)
  • HPNA/C/OR - Used for maximum heating, comes with adjustable thermostat 0-160C (32-320F)

55 US gal (200 liter) Size 'D'

  • HHNA/D/OR - Used for heating materials, comes with adjustable thermostat 0-90C (32-194F)
  • HPNA/D1/OR - Full-size jacket for high heating application, higher wattage, adjustable thermostat 0-90C (32-194F)
  • HPNA/D2/OR - Full-size jacket for high heating application, max wattage, 2 separate heating zones, adjustable thermostat 0-160C (32-320F)

Gas Bottles - Various Sizes

  • HJNA/G/OR - Used for gentle warming (freeze protection), comes with fixed thermostat 50C (122F)
  • HHNA/G/OR - Used for heating materials, comes with adjustable thermostat 0-90C (32-194F)

Base Heater - Digiheat

275gal/330gal Totes

  • HHNA/IBC1/OR - Used for gentle warming, freeze protection
  • HHNA/IBC2/OR - Used for heating material, 2 heating zones, adjustable thermostat 0-90C (32-194F)
  • HHNA/IBC3/OR - Used for maximum heating of materials, 3 heating zones, adjustable thermostat 0-90C (32-194F)

Hazardous Location Class 1 Zone 1

  • IHFNA/A/Z1 - 5gal
  • IHFNA/B/Z1 - 15gal
  • IHFNA/C/Z1 - 30gal
  • IHFNA/D/Z1 - 55gal
  • IHFNA/IBC/Z1 - IBC 1000g

Hazardous Location Class 1 Div 2

  • HJNA/A/D2 - 5gal
  • HJNA/B/D2 - 15gal
  • HJNA/C/D2 - 30gal
  • HJNA/D/D2 - 55gal
  • IHFNA/IBC/Z1 - IBC 1000g

Ordinary Location

  • HHNA/A/OR - 5gal
  • HPNA/A/OR - 5gal
  • HHNA/B/OR - 15gal
  • HPNA/B/OR - 15gal
  • HHNA/C/OR - 30gal
  • HPNA/C/OR - 30gal
  • HHNNA/D/OR - 55gal

General Info

Blanket Heaters are low watt density electrical resistance heaters that are designed for freeze protection as well as process temperature control applications. Optional pressure-sensitive adhesive makes installation easy. Heat from the blanket itself cures the silicone adhesive, creating a permanent bond. Applications include storage tanks, conveyors, water and feed troughs, dust collectors, tanks, trucks process vats, dip tanks, and melt pots. Please call (717) 630-2222 with any specifications, part numbers, model numbers, and other information such as wattage, voltage, heater length and width and lead type, with or without thermostat, lock up type, with or without adhesive, etc...and we will be happy to design a heater to match your needs.

Industrial Mica Strip Heaters

marathon_mica_strip

Mica strip heaters are only thick and .156" ideal for plate heating applications. Marathon strip heaters will operate up 900° F or to 1200° F with optional stainless steel sheath. This thin, low mass construction provides fast heat-up times.

General Info

Strip Heaters are economical heat sources, suitable for providing heat to flat surfaces. In order to avoid thermal expansion issues that detach mica strip heaters from the surfaces that they are applied to, strip heaters can be made to include several mounting holes or pressure plates that provide rigidity and improve heat transfer uniformity as well. Mica insulated strip heaters are available in many electrical termination styles, and within certain design limitations can accommodate holes and cut-outs. Industrial applications include packaging and sealing machines, food tables and warming equipment, plastic extruders, blow molding machines, ovens, hotplates, incubators, and more. Please call (717) 630-2222 with any specifications, part numbers, model numbers, and other information such as wattage, voltage, heater length and width and lead type, holes, etc...and we will be happy to design a heater to match your needs.

Finned Tubular Heaters

finned-heaters1

In applications where tubular heaters are exposed to forced convection, placing fins around tubular heaters increases their surface area and thus improves their heat transferring capacity. Finned tubular heaters, compared to regular tubular heaters, run at lower surface temperatures for the same watt densities when placed in identical air streams. Despite their advantages, finned tubular heaters are not recommended for applications where outlet air temperatures exceed 600°F.

General Info

Finned Tubular heaters-In applications where tubular heaters are exposed to forced convection, placing fins around tubular heaters increases their surface area and thus improves their heat transferring capacity. Finned tubular heaters, compared to regular tubular heaters, run at lower surface temperatures for the same watt densities when placed in identical air streams. Graph1 compares watt density, outlet air temperature, and the speed of airflow for regular and finned tubular heaters respectively. Despite their advantages, finned tubular heaters are not recommended for applications where outlet air temperatures exceed 600°F. Please call (717) 630-2222 with any specifications, part numbers, model numbers, and other information such as wattage, voltage, heater length and width and lead type, etc...and we will be happy to design a heater to match your needs.

Coil Heaters

coil-heaters

When highly focused heat is required, and a very low profile is imperative, coil heaters are the best cost-effective option. Coil heaters may be used to concentrate the heat on specific segments, or the coil may be spread to equalize the temperature across the object to be heated. Marathon Viper Coil Heater Standard Features: Flexible Teflon lead wire, available with or without internal thermocouple, 1/8" x 1/8" element cross-section, Ground Wire, 36" Stainless steel braid over leads.

General Info

Coil and Cable Heaters are high-performance mini tubular heaters that have small rectangular, square or round cross-sections that are flexible and can acquire different shapes and configurations. The sheath material of standard cable heaters are stainless 304 and their heating core is coiled or straight solid Nickel Chrome wire. Cable heaters can transmit up to 35 W/in2 heating capacity and can attain up to 15000F surface temperature. Cable heaters could be coiled, to form coil heaters that are ideal whenever a large amount of heat is required in a confined space. Coil heaters have many applications but are mostly utilized as powerful heating cells inside hot runner nozzles in plastic injection molding. Coil and cable heaters can accommodate "J" type or "K" type thermocouple sensors that could be placed internally at the tip or the middle of a heater. They can be made as well to have profiled or distributed wattage configuration. The fine electrical terminals and thermocouple wires are attached to power and thermocouple leads inside a transition adapter which has a larger diameter than the actual heater’s cross-sectional diameter. Although coil heaters and cable heaters are fully annealed and can acquire any shape, they should be formed to a final shape in a single attempt. Forming and bending operations harden the outside stainless shell of a heater, and re-annealing might become necessary if changing the form is required. Please call (717) 630-2222 with any specifications, part numbers, model numbers, and other information such as wattage, voltage, heater diameter and length and lead type, etc...and we will be happy to design a heater to match your needs.

Mica Drum Heaters

drumHeater

Featured Items:

These heaters are used to pre-heat liquids in drums or pails to make them less viscous and more flowable. They are suitable heat sources when heat is required to handle liquids during pouring, dipping, coating or mixing operations. These heaters are made to brace a drum externally and they are easily installed and removed when needed. MEGADRUM heaters are metal-sheathed, mica insulated heaters made for tough industrial applications. These heaters are fiberglass reinforced multilayer silicone rubber heaters that are flexible but rugged and durable. These heaters provide controlled heat through special thermostats.

General Info

Mica drum heaters have a rugged construction, made to withstand harsh industrial environments. Available options include a latch and trunion fastener, an insulating jacket, and a bulb and capillary adjustable thermostat. Silicone drum heaters are made of layers of fiberglass reinforced silicone rubber sheets. When these sheets are vulcanized and bonded under heat and pressure, they form a material that can withstand industrial rough usage, and is highly flexible, durable and tough. Prior to vulcanization, the electrical resistance wire web and its protective metallic grid (which acts as an electrical ground) are carefully placed between the silicone layers. Silicone drum heaters are resistant to most chemicals, fungus and moisture, and can be easily cleaned. Please call (717) 630-2222 with any specifications, part numbers, model numbers, and other information such as wattage, voltage, with or without thermostat, lock up type, etc...and we will be happy to design a heater to match your needs.

Indeeco TRIAD Washdown / Corrosion Resistant Unit Heater

indeecoTriad

The INDEECO TRIAD® unit heater is the perfect solution to the problem of heating people or equipment in non-hazardous environments where moisture and corrosion exist. Advantages of the TRIAD® include: Built-in Controls: All necessary safety and temperature controls are included in a single package. Components and motor are factory-wired to a single terminal block for field wiring, eliminating the chance for field error and reducing installation costs, Single Point Electrical Hook-up: Heater, fan motor and controls are all connected to the same branch circuit, Corrosion Resistant: Stainless steel construction, powder-coated aluminum fan blade and nonmetallic NEMA 4X terminal enclosure resist corrosion found in sewage treatment plants, swimming pool areas, car washes, paper mills and marine installations, Washable: This watertight construction can be hosed down without disconnecting the heater, which makes it ideal for coal handling areas, steel mills, foundries, ships, wood finishing plants, cement, sand, grain and food processing facilities.

General Info

Adding a fan to an electric air heater creates artificial air movement. This air movement allows for a more compact heater than the convection heater since rapidly moving air removes the heat from the heater surface more quickly. The forced air heater forces air over very long distances and is usually the choice for heating larger areas.

InteliHeat

InteliHeat
  • Thermosafe Type A
  • Thermosafe Type B
  • Faratherm Base Heater

InteliHeat

InteliHeat

Featured Items:

5 US gal (25 liter) Size 'A'

  • HJNA/A/D2 - Used for gentle warming (freeze protection), comes with fixed thermostat 50C (122F)
  • HPNA/A/D2 - Used for heating materials, comes with fixed thermostat 90C (194F)

15 US gal (50 liter) Size 'B'

  • HJNA/B/D2 - Used for gentle warming (freeze protection), comes with fixed thermostat 50C (122F)
  • HPNA/B/D2 - Used for heating materials, comes with fixed thermostat 90C (194F)

30 US gal (100 liter) Size 'C'

  • HJNA/C/D2 - Used for gentle warming (freeze protection), comes with fixed thermostat 50C (122F)
  • HPNA/C/D2 - Used for heating materials, comes with fixed thermostat 90C (194F)

55 US gal (200 liter) Size 'D'

  • HJNA/D/D2 - Used for gentle warming (freeze protection), comes with fixed thermostat 50C (122F)
  • HHNA/D/D2 - Full-size jacket for high heating application, higher wattage, fixed thermostat 90C (194F)
  • HPNA/D2/D2 - Full-size jacket for high heating application, max wattage, 2 separate heating zones, fixed thermostat 90C (194F)

Gas Bottles - Various Sizes

  • HJNA/G/D2 - Used for gentle warming (freeze protection), comes with fixed thermostat 50C (122F)
  • HHNA/G/D2 - Used for heating materials, comes with fixed thermostat 70C (158F)

275gal/330gal Totes

  • HHNA/IBC1/D2 - Used for gentle warming (freeze protection), comes with fixed thermostat 50C (122F)
  • HHNA/IBC2/D2 - Used for high heating application, higher wattage, 2 fixed thermostats 90C (194F)
  • HHNA/IBC3/D2 - Used for high heating application, max wattage, 3 separate heating zones, fixed thermostat 90C (194F)

InteliHeat

InteliHeat
  • BF400 - Only to be used in Safe Areas
  • ATEX Controller